Related Experiment Video
Updated: Jun 16, 2026

Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
Published on: May 3, 2015
Voltammetric ion-selective electrodes for the selective determination of cations and anions
Jie Zhang1, Alexander R Harris, Robert W Cattrall
1School of Chemistry and ARC Centre for Green Chemistry, Monash University, Clayton, Victoria, 3800, Australia.
Abstract:
A general theory has been developed for voltammetric ion sensing of cations and anions based on the use of an electrode coated with a membrane containing an electroactive species, an ionophore, and a supporting electrolyte dissolved in a plasticizer. In experimental studies, a membrane coated electrode is fabricated by the drop coating method. In one configuration, a glassy carbon electrode is coated with a poly(vinyl chloride) based membrane, which contains the electroactive species, ionophore, plasticizer and supporting electrolyte. In the case of a cation sensor, ionophore facilitated transfer of the target cation from the aqueous solution to the membrane phase occurs during the course of the reduction of the electroactive species present in the membrane in order to maintain charge neutrality. The formal potential is calculated from the cyclic voltammogram as the average of the reduction and oxidation peak potentials and depends on the identity and concentration of the ion present in the aqueous solution phase. A plot of the formal potential versus the logarithm of the concentration exhibits a close to Nernstian slope of RT/F millivolts per decade change in concentration when the concentration of K(+) and Na(+) is varied over the concentration range of 0.1 mM to 1 M when K(+) or Na(+) ionophores are used in the membrane. The slope is close to RT/2F millivolts for a Ca(2+) voltammetric ion-selective electrode fabricated using a Ca(2+) ionophore. The sensor measurement time is only a few seconds. Voltammetric sensors for K(+), Na(+), and Ca(2+) constructed in this manner exhibit the sensitivity and selectivity required for determination of these ions in environmentally and biologically important matrixes. Analogous principles apply to the fabrication of anion voltammetric sensors.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Ion-Exchange Chromatography
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry

