Background:
Hospitalized patients in critical care settings are at risk for bloodstream infections (BSI). Most BSIs originate from a central line (CL), and they increase length of stay, cost, and mortality. Open infusion containers may increase the risk of contamination and administration-related (CLAB) because they allow the entry of air into the system, thereby also providing an opportunity for microbial entry. Closed infusion containers were designed to overcome this flaw. However, open infusion containers are still widely used throughout the world.The objective of the study was to determine the effect of switching from open (glass, burettes, and semi-rigid) infusion containers to closed, fully collapsible, plastic infusion containers (Viaflex) on the rate and time to onset of central line-associated bloodstream infections CLABs.
Methods:
An open label, prospective cohort, active healthcare-associated infection surveillance, sequential study was conducted in four ICUs in Mexico. Centers for Disease Control National Nosocomial Infections Surveillance Systems definitions were used to define device-associated infections.
Results:
A total of 1,096 adult patients who had a central line in place for >24 hours were enrolled. The CLAB rate was significantly higher during the open versus the closed container period (16.1 versus 3.2 CLAB/1000 central line days; RR = 0.20, 95% CI = 0.11-0.36, P < 0.0001). The probability of developing CLAB remained relatively constant in the closed container period (1.4% Days 2-4 to 0.5% Days 8-10), but increased in the open container period (4.9% Days 2-4 to 5.4% Days 8-10). The chance of acquiring a CLAB was significantly decreased (81%) in the closed container period (Cox proportional hazard ratio 0.19, P < 0.0001). Mortality was statistically significantly lower during the closed versus the open container period (23.4% versus 16.1%; RR = 0.69, 95% CI = 0.54-0.88, P < 0.01).
Conclusions:
Closed infusion containers significantly reduced CLAB rate, the probability of acquiring CLAB, and mortality.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Endocarditis IV: Nursing Management
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...