Related Experiment Video
Updated: Jun 16, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
The performance of columns packed with the new 2.6 microm Kinetex-C(18) shell particles was investigated in gradient elution chromatography and compared with those of the 2.7 microm Halo-C(18) shell particles and the 1.7 microm BEH-C(18) totally porous particles. The peak capacities P(c) of these columns were derived from the resolution of the components of a peptide mixture (beta-Lactoglobulin digest) and of a mixture of two biomolecules (insulin and lyzozyme).The three columns exhibit the same peak capacities for the peptides at low linear velocity (u(0) < 0.05 cm/s) and at any gradient steepness (0.8 < G < 10). When the linear velocity is increased 10-fold, the peak capacity of the Kinetex column remains nearly unchanged while those of the Halo-C(18) and the BEH-C(18) columns decrease by 20%, approximately. This result confirms the very flat HETP curve, the very low C term of the Kinetex column and its ability to successfully operate at high flow rates while experiencing less efficiency loss than other columns. Despite its smaller average mesopore size (96 A versus 130 A), the column packed with 2.6 microm shell Kinetex-C(18) particles gives an equivalent or even slightly better separation of biomolecules having a size and a mass around 40 A and 15 kDa, respectively, than the column packed with 1.7 microm BEH-C(18) totally porous particles. This result demonstrates the advantages of the shell versus the conventional particle technology when it comes to resolve mixtures of large and slow diffusive biomolecules.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography
Ion-Exchange Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
