Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Molecular Spectroscopy: Absorption and Emission01:14

Molecular Spectroscopy: Absorption and Emission

Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Long-path high-resolution atmospheric transmission measurements: comparison with LOWTRAN 3B predictions; comments.

Applied optics·2010
Same author

AFGL trace gas compilation.

Applied optics·2010
Same author

Updating of the AFCRL atmospheric absorption line parameters compilation.

Applied optics·2010
Same author

Balloon observations of the radiance of the earth between 2100 cm(-1) and 2700 cm(-1).

Applied optics·2010
Same author

l-TYPE DOUBLING IN NH(3).

Proceedings of the National Academy of Sciences of the United States of America·1958
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 16, 2026

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
07:38

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared

Published on: January 10, 2025

Atmospheric absorption line compilation

J S Garing, R A McClatchey

    Applied Optics
    |February 4, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
    09:40

    Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown

    Published on: February 14, 2014

    Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs
    07:51

    Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs

    Published on: August 27, 2019

    Related Experiment Videos

    Last Updated: Jun 16, 2026

    Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
    07:38

    Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared

    Published on: January 10, 2025

    Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
    09:40

    Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown

    Published on: February 14, 2014

    Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs
    07:51

    Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs

    Published on: August 27, 2019