Performance of 'energy efficient' compact fluorescent lamps
Gloria S-C Yuen1, Alistair B Sproul, Stephen J Dain
1University of New South Wales, Sydney, Australia.
Clinical & Experimental Optometry
|February 6, 2010
Summary
Compact fluorescent lamps (CFLs) generally meet lighting standards, but wattage equivalence claims are often unsubstantiated. Differences in light distribution mean CFLs may not be direct incandescent replacements.
Area of Science:
- Lighting Technology
- Energy Efficiency
Background:
- Public dissatisfaction exists regarding the light output and color of compact fluorescent lamps (CFLs).
- Independent verification of CFL performance claims and compliance with Australian/New Zealand Standards is lacking.
- While luminous flux may meet standards, luminous intensity distributions can differ significantly from incandescent bulbs.
Purpose of the Study:
- To independently examine compact fluorescent lamp (CFL) performance against manufacturer claims and Australian/New Zealand Standards.
- To assess the accuracy of 75 W equivalence claims for CFLs.
- To compare the luminous intensity distribution of CFLs with incandescent globes.
Main Methods:
- Measured luminous intensity distribution, luminous flux, and spectral energy distribution of CFLs and 75 W incandescent globes.
- Calculated luminous flux, luminous efficacy, color rendering index, correlated color temperature, wattage, and power factor.
- Compared measurements with manufacturer claims and standard requirements.
Main Results:
- CFLs generally complied with standards for luminous flux, luminous efficacy, color rendering index, and correlated color temperature.
- Claims of 75 W equivalence were justified less than 50% of the time and are not regulated in Australia/New Zealand.
- Biaxial CFLs exhibited distinct differences in luminous intensity distribution compared to incandescent lamps.
Conclusions:
- Compact fluorescent lamps (CFLs) typically meet established lighting standards.
- The basis for claimed equivalent wattages should be incorporated into Australian and New Zealand standards for public clarity.
- Differences in luminous intensity distribution necessitate careful consideration when replacing incandescent sources with CFLs.
Related Concept Videos
Electrical Energy
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules. The...
Fluorescence and Phosphorescence: Instrumentation
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Variables Affecting Phosphorescence and Fluorescence
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
Photoluminescence: Applications
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...