Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Interference and Diffraction02:18

Interference and Diffraction

Interference is a characteristic phenomenon exhibited by waves. When two electromagnetic waves interact with their peaks and troughs coinciding, a resulting wave with enhanced amplitude is produced. This is known as constructive interference. In this case, the two waves interacting are in phase with each other.
Adjusting a Traverse01:12

Adjusting a Traverse

In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
Reflective Property of Parabolas01:26

Reflective Property of Parabolas

A parabola is a basic type of conic section that results from the intersection of a plane with a double-napped cone in a direction parallel to one of the cone's sides. This U-shaped curve has a distinctive reflective property: all incoming rays parallel to its axis of symmetry are directed toward a single point, known as the focus. This property is widely utilized in optical and communication technologies that require precise signal concentration.In analytic geometry, a parabola is defined as...
Errors in Taping01:18

Errors in Taping

Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Synthesis of silicon nitride and silicon oxide films by ion-assisted deposition.

Applied optics·2010
Same author

Influence of ion assistance on the optical properties of MgF(2).

Applied optics·2010
Same author

Ion-assisted deposition of magnesium fluoride films on substrates at ambient temperatures.

Applied optics·2010
Same author

Measuring small ac Faraday rotation: a novel method.

Applied optics·2010
Same author

Hydrogenated carbon films produced by sputtering in argon-hydrogen mixtures.

Applied optics·2010
Same author

Coating Fabry-Perot interferometer plates with broadband multilayer dielectric mirrors.

Applied optics·2010

Related Experiment Video

Updated: Jun 16, 2026

The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
12:14

The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

Published on: August 12, 2013

Correction of parabolic errors in fabry-perot interferometers.

R P Netterfield, J V Ramsay

    Applied Optics
    |February 6, 2010
    PubMed
    Summary

    This study presents a method to correct parabolic errors in Fabry-Perot interferometers. The technique significantly enhances precision, reducing errors from lambda/50 to less than lambda/400.

    Area of Science:

    • Optical Physics
    • Interferometry

    Background:

    • Fabry-Perot interferometers are crucial for high-resolution spectroscopy.
    • Parabolic errors can limit the precision of these instruments.

    Purpose of the Study:

    • To develop and demonstrate a method for correcting parabolic errors in Fabry-Perot interferometers.
    • To improve the accuracy and performance of these optical devices.

    Main Methods:

    • Utilizing evaporated films for optical coating.
    • Implementing an appropriate shutter mechanism for error correction.
    • Applying the method to reduce parabolic aberrations.

    Main Results:

    • Successfully reduced significant parabolic errors (lambda/50) to a minimal level (less than lambda/400).

    More Related Videos

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
    07:22

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon

    Published on: February 3, 2023

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    Related Experiment Videos

    Last Updated: Jun 16, 2026

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
    12:14

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

    Published on: August 12, 2013

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
    07:22

    Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon

    Published on: February 3, 2023

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

  • Demonstrated effectiveness over substantial apertures (54-mm).
  • Achieved high precision at a wavelength of approximately 550 nm.
  • Conclusions:

    • The described method offers an effective solution for correcting parabolic errors in Fabry-Perot interferometers.
    • This technique enhances the precision and reliability of interferometric measurements.
    • Evaporated films and shutter systems provide a practical approach to improving optical instrument performance.