Screening of pesticides in blood with liquid chromatography-linear ion trap mass spectrometry
Sylvain Dulaurent1, Christian Moesch, Pierre Marquet
1Department of Pharmacology and Toxicology, CHU de Limoges, 87042 Limoges, France. sylvain.dulaurent@unilim.fr
Abstract:
In clinical or forensic toxicology, general unknown screening procedures are used to identify as many xenobiotics as possible, belonging to numerous chemical classes. We present here a general unknown screening procedure based on liquid chromatography coupled with use of a single linear ion trap mass spectrometer, and focus on the identification of pesticides and/or metabolites in whole blood. After solid-phase extraction (SPE), the compounds of interest were separated using a reversed-phase column and identified by the mass spectrometer operated first in the full-scan mass spectrometry (MS) mode, in the positive and negative polarities, followed by MS(2) and MS(3) scanning of ions selected in data-dependent acquisition. The total scan time was 2.45 s. Two mass spectral libraries (MS(2) and MS(3)), each of 450 spectra, were created for the 320 pesticides and metabolites detected after injection of pure solutions. Robustness of the spectra and matrix effects were studied and were satisfactory for the present application. Detection limits for the 320 compounds were studied by extracting 1 mL spiked blood at concentrations between 10 microg/L and 10 mg/L. If necessary, it was possible to decrease the detection limits of some compounds by 10-100-fold by scanning MS(2) in only one polarity, owing to a shorter total scan time. However, at the same time, the detection specificity decreased as no confirmation could be recorded in the following MS(3) scan and no information could be registered in the other polarity. So, in these rare cases, confirmation by another method was required.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
05:52Histone Modification Screening using Liquid Chromatography, Trapped Ion Mobility Spectrometry, and Time-Of-Flight Mass Spectrometry
Published on: January 12, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...