Related Experiment Video
Updated: Jun 16, 2026

An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps
Published on: December 5, 2025
Refining perforator selection for DIEP breast reconstruction using transit time flow volume measurements
Kari Visscher1, Kirsty Boyd, Douglas C Ross
1Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
Transit time flow volume (TTFV) accurately identifies arterial perforators in deep inferior epigastric artery perforator (DIEP) flap surgery. This method offers high sensitivity and specificity, improving flap perfusion and preventing complications.
Area of Science:
- Vascular Surgery
- Microsurgery
- Medical Imaging
Background:
- Transit time flow volume (TTFV) is established for assessing small vessel flow in cardiac surgery.
- Deep inferior epigastric artery perforator (DIEP) flap harvesting requires precise identification of perforator vessels.
- Current methods for perforator assessment may have limitations.
Purpose of the Study:
- To evaluate the utility of TTFV in assessing perforator vessels during DIEP flap harvesting.
- To correlate TTFV measurements with computed tomographic angiography (CTA) and hand-held Doppler signals.
- To determine the accuracy of TTFV in identifying arterial perforators.
Main Methods:
- Prospective evaluation of ten free DIEP breast reconstructions.
- Preoperative CTA to identify abdominal wall perforators.
- Intraoperative assessment of perforators (>1 mm) using hand-held Doppler and TTFV device.
- Correlation of vessel location, waveform patterns, and TTFV with CTA and Doppler findings.
Main Results:
- TTFV demonstrated arterial flow waveforms in 15 of 16 CTA-identified perforators and 2 additional vessels.
- TTFV achieved 94% sensitivity and 95% specificity in identifying arterial perforators.
- Hand-held Doppler was misleading in 70% of assessed vessels.
- TTFV effectively distinguished arterial from venous waveforms, even when Doppler signals were ambiguous.
Conclusions:
- TTFV is a highly accurate tool for identifying arterial perforators in DIEP flap harvesting.
- CTA and TTFV show strong correlation, enhancing perforator vessel assessment.
- Utilizing TTFV may help prevent poor flap perfusion and improve surgical outcomes.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
11:12In situ Transverse Rectus Abdominis Myocutaneous Flap: A Rat Model of Myocutaneous Ischemia Reperfusion Injury
Published on: June 8, 2013