Change point analysis for longitudinal physiological data: detection of cardio-respiratory changes preceding panic
David Rosenfield1, Enlu Zhou, Frank H Wilhelm
1Department of Psychology, Southern Methodist University, 6424 Hilltop Lane, Dallas, TX 75275, USA. drosenfi@smu.edu
Biological Psychology
|February 11, 2010
Summary
Change point analysis successfully detected physiological changes before panic attacks (PAs). This method identified unique cardio-respiratory shifts preceding PAs, unlike control periods, supporting panic etiology theories.
Area of Science:
- Psychophysiology
- Time Series Analysis
- Biomedical Data Science
Background:
- Existing statistical methods like ANOVA and mixed models are inadequate for detecting unknown changes in longitudinal psychophysiological data.
- Change point (CP) analysis is a statistical technique designed to identify distinct shifts in time series data.
- Preliminary studies show promise for CP analysis in analyzing functional magnetic resonance imaging (fMRI) data.
Purpose of the Study:
- To apply CP analysis to ambulatory, peripheral physiological data for detecting discrete changes preceding naturally occurring panic attacks (PAs).
- To evaluate the efficacy of CP analysis in identifying physiological alterations specific to the pre-panic attack period.
Main Methods:
- Utilized change point (CP) analysis on longitudinal, ambulatory psychophysiological data.
- Applied the CP method to identify discrete changes in cardio-respiratory data leading up to panic attacks.
- Compared physiological changes during pre-panic attack periods with matched non-panic attack control periods.
Main Results:
- The CP method successfully identified significant cardio-respiratory changes that preceded the onset of reported panic attacks.
- These detected physiological changes were specific to the pre-panic attack period and were not observed during control periods.
- The identified patterns of change aligned with established respiratory theories of panic, suggesting a link between aberrant respiration and panic etiology.
Conclusions:
- Change point analysis is an effective tool for detecting specific physiological changes associated with panic attacks in time series data.
- The findings support the role of aberrant respiration in the etiology of panic attacks.
- CP analysis offers a valuable statistical approach for understanding the dynamics of psychophysiological responses during panic episodes.
Related Concept Videos
Panic Disorder
Panic disorder is an anxiety disorder characterized by recurrent and sudden minutes-long episodes of intense fear, known as panic attacks. These attacks may feel like heart attacks and often happen without warning or a specific cause. They can include symptoms such as rapid heart rate, shortness of breath, chest pain, trembling, sweating, dizziness, and a sense of helplessness. During a panic attack, individuals may feel as though they are experiencing a heart attack or are in a...
Measurement of Blood Pressure
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.