Related Experiment Video
Updated: Jun 16, 2026

Setup for the Quantitative Assessment of Motion and Muscle Activity During a Virtual Modified Box and Block Test
Published on: January 12, 2024
Acute effects of Flexi-bar vs. Sham-bar exercise on muscle electromyography activity and performance
Katya N Mileva1, Miran Kadr, Noim Amin
1Sport and Exercise Science Research Center, Academy of Sport, FESBE, London South Bank University, London, United Kingdom. milevakn@lsbu.ac.uk
Abstract:
This study was conducted to investigate whether the low-frequency (5-Hz) oscillatory vibration-like stimulus, purported to be delivered by exercising with Flexi-bar, acutely affects muscle activation and maximal voluntary contraction (MVC) force. Nine healthy men participated in 2 trials, separated by at least 1 week, during which 4 x 30-second sets of exercise were performed with either the Flexi bar or a Sham bar. Maximal voluntary contraction force for elbow flexion, elbow extension, and knee extension were measured before and after the exercise. Root-mean-square amplitude and median frequency of electromyography (EMG) signal were calculated for the first and last 10 seconds of each exercise set and during the MVCs from biceps brachii (BB), triceps brachii (TB), rectus femoris (RF), and vastus lateralis (VL) for each trial. Electromyography amplitude was significantly higher for all studied muscles during Flexi-bar than Sham-bar exercise (32-203%, p < 0.05). Median frequency of EMG power spectrum was significantly lower in arm (TB: -40 +/- 13%, p < 0.0001; BB: -32 +/- 25%, p = 0.015) but not in leg (RF: -12 +/- 18%; VL: +6 +/- 32%; p > 0.05) muscles during Flexi-bar compared with Sham-bar exercise. Knee extension MVC force significantly decreased after Flexi-bar exercise (-3 +/- 7%, p = 0.048) in parallel with reduced RF EMG amplitude (-8 +/- 5%, p = 0.04), but there were no acute residual effects on elbow flexion/extension MVC or arm and VL EMG muscle activity. Using Flexi bar during exercise provoked acute alterations in arm- and leg-muscle EMG parameters and maximum force-generating capacity, indicating greater fatigue development than when exercising with the Sham bar. The results of this study indicate that Flexi bar may therefore be used to impose a stronger training stimulus on the muscle during submaximal exercise.
Related Concept Videos
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...

