Related Experiment Video
Updated: Jun 16, 2026

The Nijmegen Hemostasis Assay: Simultaneous Fluorogenic Measurement of Thrombin and Plasmin Generation in a Single Well
Published on: February 27, 2026
Thrombin generation in haemophilia A patients with mutations causing factor VIII assay discrepancy
R Gilmore1, S Harmon, C Gannon
1Haemostasis Research Group, Institute of Molecular Medicine, Trinity Centre for Health Sciences, St James's Hospital, Dublin, Ireland.
Mild hemophilia A patients with factor VIII (FVIII) assay discrepancies show reduced thrombin generation. The one-stage clotting assay better reflects coagulation potential than the chromogenic assay in these patients.
Area of Science:
- Hematology
- Coagulation Science
- Clinical Diagnostics
Background:
- Mild hemophilia A patients often exhibit discrepancies between factor VIII (FVIII) measurements from one-stage clotting assays (FVIII:C) and two-stage chromogenic assays (FVIII:C(CH)).
- The clinical significance of this assay discrepancy and which assay better represents coagulation potential remains unclear.
Purpose of the Study:
- To assess the global coagulant ability in hemophilia A patients with FVIII assay discrepancy using calibrated automated thrombography (CAT).
- To determine which FVIII assay correlates better with thrombin generation parameters in patients with assay discrepancies.
Main Methods:
- Investigated 18 patients with FVIII assay discrepancy (Arg531His/Cys or Arg698Trp mutations), 12 with concordant FVIII values, and 15 healthy controls.
- Measured FVIII levels using both one-stage clotting and two-stage chromogenic assays.
- Assessed thrombin generation in platelet-poor plasma using CAT with low tissue factor (1 pm).
Main Results:
- FVIII:C(CH) values were lower than FVIII:C in the discrepant group (1.5- to 8-fold).
- All hemophilia patients showed affected CAT parameters; endogenous thrombin potential (ETP) was reduced (58-67% of normal), and peak thrombin was significantly reduced (27-30% of normal) in both discrepant and concordant groups.
- The FVIII:C assay showed the strongest correlation with ETP (r²=0.44) and peak thrombin (r²=0.27) in the discrepant group.
Conclusions:
- Calibrated automated thrombography reveals impaired thrombin generation in hemophilia A patients, irrespective of FVIII assay discrepancy.
- The one-stage FVIII:C assay appears to better reflect the global coagulant ability and thrombin generation potential compared to the FVIII:C(CH) assay in patients with mild hemophilia A and assay discrepancies.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Venous Thrombosis III: Interprofessional Care
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...