Related Experiment Video
Updated: Jun 16, 2026

Polarization-Sensitive Two-Photon Microscopy for a Label-Free Amyloid Structural Characterization
Published on: September 8, 2023
Scanning orientation and polarization effects for XRQA radiochromic film
Hani Alnawaf1, Martin J Butson, Tsang Cheung
1Centre for Medical Radiation Physics, University of Wollongong, Gwynneville, NSW, Australia.
Abstract:
Gafchromic XRQA radiochromic film, is an effective tool for quality assurance and dose assessment in kilovoltage radiotherapy and diagnostic applications. Like other Gafchromic film products, XRQA film exhibits a variation in dose to reflected optical density response with angle of rotation when analysed with a light source that is partially or fully polarised such as a desktop scanner. Although warnings are not given on manufacturers specifications, this can affect dosimetry accuracy and we recommend that it is essential to scan all XRQA films in the same orientation. The effect is not as pronounced as EBT Gafchromic film. The magnitude of this variation has been measured and shown to be up to 16 ± 2% (1SD) using a fully linear polarised light source was seen with a 90° angle rotation. This would be the maximum variation seen on a desktop scanner with a fully polarised light source. For our standard desktop scanner (Epson v700) a mean variation of 2 ± 1% from 0 cGy to 20 cGy applied dose was measured as compared to 8 ± 2% for EBT Gafchromic. We recommend that to decrease uncertainty in dose measurement, accurate alignment of the calibration films to experimental films be performed on a regular basis. This is especially important if your desktop scanner has a high degree of polarization of its light source.
More Related Videos
09:55Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
Published on: January 5, 2024
08:01Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo
Published on: September 26, 2016
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Nuclei: Magnetic Resonance
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Imaging
Atomic Nuclei: Nuclear Relaxation Processes