Formulation of 68Ga BAPEN kit for myocardial positron emission tomography imaging and biodistribution study
Bo Yeun Yang1, Jae Min Jeong, Young Joo Kim
1Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, 110-744 Seoul, South Korea.
Introduction:
Tris(4,6-dimethoxysalicylaldimine)-N,N'-bis(3-aminopropyl)-N,N'-ethylenediamine (BAPEN), a tris(salicylaldimine) derivative, is a heart positron emission tomography (PET) agent when labeled with (68)Ga. However, its labeling requires complicated and time-consuming procedures. In this study, the authors formulated a new BAPEN kit for convenient (68)Ga labeling.
Methods:
BAPEN (0.25 mg) kits were prepared by dispensing its solution in 1 M sodium acetate buffer (pH 5.5) into sterile vials and lyophilization. The prepared kits were labeled with generator-eluted (68)Ga in 0.1 N HCl. Stability in human serum was tested. Expiration date was determined by accelerated testing according to US Food and Drug Administration guidelines. A Biodistribution study was performed in normal mice after injection via tail vein.
Results:
The prepared kits achieved radiolabeling efficiencies in excess of 95% and showed a shelf-life of 98 days at 25 degrees C and 64.3 months at 4 degrees C. (68)Ga-BAPEN was found to be stable in human serum at 37 degrees C for at least 1 h. Furthermore, a biodistribution study revealed high heart uptake (10.8% ID/g, 1 h).
Conclusions:
The authors developed a BAPEN kit for convenient labeling with (68)Ga. The (68)Ga-BAPEN showed high stability and excellent biodistribution results in normal mice, which is required for myocardial PET imaging.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)