Related Experiment Video
Updated: Jun 16, 2026

08:29
A 3D-printed Chamber for Organic Optoelectronic Device Degradation Testing
Published on: August 10, 2018
Vacuum decay container/closure integrity testing technology. Part 2. Comparison to dye ingress tests.
Heinz Wolf1, Tony Stauffer, Shu-Chen Y Chen
1Packaging Technologies & Inspection, LLC, Tuckahoe, NY 10707, USA.
PDA Journal of Pharmaceutical Science and Technology
|February 18, 2010
Summary
Vacuum decay leak testing reliably detects small defects in prefilled syringes. Standard dye ingress tests struggle with consistency and accuracy, posing risks of false results for container closure integrity.
Area of Science:
- Pharmaceutical Packaging
- Analytical Chemistry
- Materials Science
Background:
- Container closure integrity is critical for sterile drug product quality.
- Traditional dye ingress tests have limitations in detecting small defects.
- Previous studies indicated vacuum decay leak testing's potential for package integrity.
Purpose of the Study:
- Compare dye ingress methods (USP, Ph.Eur., ISO) against vacuum decay leak testing.
- Evaluate the detection of 5-15 micrometer defects in prefilled syringes.
- Assess the reliability and accuracy of different integrity test methods.
Main Methods:
- Utilized ASTM F2338-09 standard for vacuum decay leak testing (VeriPac 325/LV).
- Performed comparative analysis with USP, Ph.Eur., and ISO dye ingress tests.
- Tested 1-mL glass prefilled syringes with laser-drilled holes (5, 10, 15 micrometers).
- Study conducted across three sites with multiple inspectors and varied conditions.
Main Results:
- No standard dye ingress method reliably detected all defects.
- Modified dye ingress conditions improved detection but increased false positive risk.
- Vacuum decay leak testing consistently identified defects as small as 5 micrometers.
- Nondestructive vacuum decay method demonstrated superior reliability.
Conclusions:
- Vacuum decay leak testing offers a reliable method for container closure integrity testing of prefilled syringes.
- Standard dye ingress tests require significant modification to approach the reliability of vacuum decay testing.
- The VeriPac 325/LV vacuum decay method is effective for detecting critical defects in pharmaceutical packaging.