Related Experiment Video
Updated: Jun 16, 2026

Multi-enzyme Screening Using a High-throughput Genetic Enzyme Screening System
Published on: August 8, 2016
Development and validation of a transcreener assay for detection of AMP- and GMP-producing enzymes
Matt Staeben1, Karen M Kleman-Leyer, Andrew L Kopp
1BellBrook Labs, Madison, Wisconsin, USA. matt.staeben@bellbrooklabs.com
Abstract:
Screening of AMP- and GMP-producing enzymes such as phosphodiesterases (PDEs), ligases, and synthetases would be simplified by the ability to directly detect unmodified nucleoside monophosphates. To address this need, we developed polyclonal and monoclonal antibodies that recognize AMP and GMP with nanomolar sensitivity and high selectivity vs. the corresponding triphosphate and 3',5'-cyclic monophosphate nucleotides that serve as substrates for many enzymes in these classes. One of these antibodies was used to develop a Transcreener AMP/GMP assay with a far red fluorescence polarization (FP) readout. This polyclonal antibody exhibited extremely high selectivity, with IC(50) ratios of 6,000 for ATP/AMP, 3,810 for cAMP/AMP, and 6,970 for cGMP/GMP. Standard curves mimicking enzymatic conversion of cAMP, cGMP, and ATP to the corresponding monophosphates yielded Z' values of >0.85 at 10% conversion. The assay reagents were shown to be stable for 24 h at room temperature, both before and after dispensing. The Transcreener AMP/GMP FP assay was used for enzymatic detection of cGMP- and cAMP-dependent PDEs 4A1A, 3A, and 9A2 and ATP-dependent ligases, acetyl CoA synthetase, and ubiquitin- activating enzyme (UBE1). Shifts of >100 mP were observed in the linear part of the progress curves for all enzymes tested, and the PDE isoforms exhibited the expected substrate and inhibitor selectivity. These studies demonstrate that direct immunodetection of AMP and GMP is a flexible, robust enzyme assay method for diverse AMP- and GMP-producing enzymes. Moreover, it eliminates many of the shortcomings of other methods including the need for fluorescently labeled substrates, the low signal:background inherent in substrate depletion assays, and the potential for interference with coupling enzymes.
More Related Videos
07:13Developing Custom Chinese Hamster Ovary-host Cell Protein Assays using Acoustic Membrane Microparticle Technology
Published on: February 3, 2011
11:31Establishment of a High-throughput Setup for Screening Small Molecules That Modulate c-di-GMP Signaling in Pseudomonas aeruginosa
Published on: June 30, 2016