Evaluation of coronary artery in-stent restenosis by 64-section computed tomography: factors affecting assessment and accurate diagnosis
Related Experiment Video
Updated: Jun 16, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Sang-Hoon Chung1, Young Jin Kim, Jin Hur
1Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University Medical Center, Seodaemun-gu, Seoul, Korea.
Purpose:
To determine factors affecting the ability of 64-multislice computed tomography (MSCT) to detect, assess, and accurately diagnose significant coronary arterial in-stent restenosis (ISR).
Materials And Methods:
The institutional review board approved this study and waived informed consent. Sixty patients underwent CT coronary angiography using 64-MSCT, after implantation of coronary artery stents (n=91). We assessed diagnostic accuracy for ISR with CT in comparison with conventional coronary angiography as the gold standard, visually and with measurement of in-stent coronary lumen density. Possible factors that influenced the diagnostic performance of CT were evaluated, which included image quality (IQ), stent characteristics, and location.
Results:
Sixty-nine stents (75.8%) were assessable. Low IQ, location in the left circumflex coronary artery, and narrow stent diameter were associated with poor assessment (P<0.05). In stents that could be assessed, sensitivity, specificity, positive predictive value, and negative predictive value of 64-MSCT were 90.0%, 73.5%, 58.1%, and 94.7%, respectively, for significant ISR. The diagnostic accuracy in assessable stents showed a significant increase with better IQ, thinner strut thickness, and nondrug eluting stent. False-positive diagnoses of ISR by CT were explained by coronary lumen density measurements.
Conclusions:
Evaluation of stents by 64-MSCT is not recommended in stents with diameters of < or = 2.75 mm or stents located at the left circumflex coronary artery. The diagnostic accuracy of 64-MSCT is affected by IQ and strut thickness in assessable stents. Significant ISR can be excluded with high reliability in selected patients.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Coronary Artery Disease V: Interprofessional Care

