Nasal suction technique for maxillary sinus floor elevation: a report of 24 consecutive patients
1Dental Implantology, University of Salford, United Kingdom. ucer@oral-implants.com
Purpose:
Inadvertent perforation of the sinus membrane is a frequent complication encountered during sinus floor elevation (SFE). Different strategies have been described for the prevention or treatment of perforations, with varying results. This paper reports the findings of a preliminary study into the application of a novel nasal suction technique in which negative antral air pressure was used to facilitate the raising of the sinus lining and to reduce the risk of perforations occurring during SFE.
Materials And Methods:
In 24 consecutive patients, nasal suction was applied through the ipsilateral nostril during SFE. The suction device was attached to a high-flow vacuum regulator that incorporated a suction canister connected to a -10-kPA medical vacuum (-75 mm Hg). Fifteen subjects received unilateral SFE, and six subjects had bilateral staged lateral wall sinus elevation; the remaining three subjects had osteotome sinus floor elevation (three unilateral and one bilateral) with simultaneous implant placement.
Results:
During SFE, the use of nasal suction facilitated the inversion of the sinus lining around the edges of the lateral access window. This made the sinus lifting easier, as the need for extensive instrumentation was significantly reduced. In three subjects, elevation of the sinus lining occurred spontaneously from the lateral, medial, and inferior surfaces of the antrum when nasal suction was applied.
Conclusion:
Sinus lifting was facilitated by nasal suction. No perforation of the sinus lining occurred in this series. Controlled clinical trials are being designed to further demonstrate the clinical efficacy of the nasal suction technique in SFE.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning II: Procedure
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Cardiopulmonary Resuscitation II: ACLS Airway Management