Related Experiment Video
Updated: Jun 16, 2026

Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
Bedside assessment of mean systemic filling pressure
Jos R C Jansen1, Jacinta J Maas, Michael R Pinsky
1Department of Intensive Care Medicine, Leiden University Medical Center, The Netherlands. jrcjansen@lumc.nl <jrcjansen@lumc.nl>
Purpose Of Review:
The physiology of the venous part of the human circulation seems to be a forgotten component of the circulation in critical care medicine. One of the main reasons, probably, is that measures of right atrial pressure (Pra) do not seem to be directly linked to blood flow. This perception is primarily due to an inability to measure the pressure gradient for venous return. The upstream pressure for venous return is mean systemic filling pressure (Pmsf) and it does not lend itself easily to be measured. Recent clinical studies now demonstrate the basic principles underpinning the measure of Pmsf at the bedside.
Recent Findings:
Using routinely available minimally invasive monitoring of continuous cardiac output and Pra, one can accurately construct venous return curves by performing a series of end-inspiratory hold maneuvers, in ventilator-dependent patients. From these venous return curves, the clinician can now finally obtain at the bedside not only Pmsf but also the derived parameters: resistance to venous return, systemic compliance and stressed volume.
Summary:
Measurement of Pmsf is essential to describe the control of vascular capacitance. It is the key to distinguish between passive and active mechanisms of blood volume redistribution and partitioning total blood volume in stressed and unstressed volume.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure