Related Experiment Video
Updated: Jun 16, 2026

06:46
Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
X-ray calibration of RAR 2490 film for application to laser plasma experiments
Applied Optics
|February 20, 2010
Summary
This study calibrated Kodak RAR 2490 film
Area of Science:
- Radiological Sciences
- Materials Science
Background:
- Accurate X-ray film calibration is crucial for quantitative imaging.
- Kodak RAR 2490 film is a common choice for X-ray applications.
Purpose of the Study:
- To perform a comprehensive sensitometric calibration of Kodak RAR 2490 film.
- To determine the film's response across a wide range of X-ray photon energies.
- To analyze the characteristic curves and identify solarization effects.
Main Methods:
- X-ray sensitometric calibration was conducted.
- Photon energies ranged from 0.28 to 8.04 keV.
- Characteristic curves (optical density vs. exposure) were analyzed and fitted to an analytic function.
Main Results:
- The characteristic curves were well-described by a two-parameter analytic function: log10(10^D - 1) = A log10(H) + B.
- Solarization was observed at 1.49 keV with an exposure threshold of 2 x 10^3 photons/μm².
- The film's performance was compared to other available films.
Conclusions:
- The analytic function provides a robust model for Kodak RAR 2490 film's sensitometric response.
- Understanding solarization is critical for accurate exposure determination in specific X-ray energy ranges.
- This calibration data aids in selecting appropriate films for various X-ray imaging tasks.