Related Experiment Video
Updated: Jun 16, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement
Tugrul Göncü1, Mustafa Sezen, Hasan Ari
1Department of Cardiovascular Surgery, Bursa Yüksek Ihtisas Education and Research Hospital, Bursa, Turkey.
Abstract:
Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.