Lossy JPEG compression in quantitative angiography: the role of X-ray quantum noise
Johannes Peter Fritsch1, Rüdiger Brennecke
1Department of Information Technology, University Medical Center of the Johannes Gutenberg University, Langenbeckstrasse 1, Mainz, Germany. jp.fritsch@unimedizin-mainz.de
Abstract:
In medical imaging, contrary to applications in the consumer market, the use of irreversible or lossy compression is still in its beginnings. This is due to the suspected risk of compromising the diagnostic content. Many studies have been performed, but it was not until 2008 that national activities in different countries resulted in recommendations for the safe use of irreversible image compression in clinical practice. Quantitative coronary angiography (QCA), however, poses a special problem, since here a large variation in published maximum compression factors has strengthened the general concerns about the use of lossy techniques. Up to now, the reason for the variation has not been thoroughly investigated. Reasons for the discrepancies in published compression factors are determined in this study. Since JPEG compression reduces the quantum noise of the X-ray images, the impact of compression is overestimated when interpreting any change in local diameter as an error. By taking into consideration the quantitative effect of quantum noise in QCA, it is shown that the influence of JPEG compression can be neglected for compression factors up to ten at clinically applicable X-ray doses. This limit is comparable to that found by visual analysis for aesthetic image quality. Future studies on image compression effects should take the interaction with quantum noise explicitly into consideration.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...