Related Experiment Video
Updated: Jun 16, 2026

Porcine Liver Transplantation Without Veno-Venous Bypass As an Extended Criteria Donor Model
Published on: August 17, 2022
[Effectiveness of continuous central venous oxymetry in living-donor liver transplantation with massive bleeding]
Yoko Kawaguchi1, Tetsuya Kushikata, Hajime Takase
1Department of Anesthesiology, Hirosaki University Graduate School of Medicine, Hirosaki 036-8562.
Abstract:
In living relative liver transplantation, patients are exposed to enormous stress and multifaced monitors are required to evaluate physiologic status of the patient such as blood volume, electrolytes balance, clotting ability and metabolic status including oxygen consumption. To maintain transplanted liver graft function, an adequate oxygen supply to the graft is one of the most important factors. Central venous oxygen saturation is minimally invasive and one of the most useful monitor to evaluate the oxygen demand and supply balance in the graft. A continuous central venous oximetry (PreSep, Edwards Lifesciences, Tokyo, JAPAN) was used. The use of the oxymetry to evaluate oxygen demand and supply balance in a living relative liver transplantation especially in a case of massive bleeding was very effective.