Related Experiment Video
Updated: Jun 16, 2026

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet (VUV) Synchrotron Radiation
Published on: October 30, 2012
International exercise on 124Sb photon emission intensities determination
M-M Bé1, B Chauvenet, M-N Amiot
1Laboratoire National Henri Becquerel (LNE-LNHB), CEA, LIST, F 91191 Gif-sur-Yvette Cedex, France. mmbe@cea.fr
An international exercise involving eight laboratories measured the activity and photon emission intensities of Antimony-124 (124Sb). Results confirmed that activity measurement issues were not caused by the decay scheme data.
Area of Science:
- Nuclear physics
- Metrology
- Radiochemistry
Background:
- Accurate measurement of radionuclide activity and decay properties is crucial for various scientific and industrial applications.
- International comparisons are essential for validating measurement techniques and ensuring data consistency across different laboratories.
Purpose of the Study:
- To conduct an international exercise (EUROMET project no. 907) to measure the activity of an Antimony-124 (124Sb) solution.
- To determine the photon emission intensities of 124Sb decay.
- To identify potential sources of discrepancies in activity measurements.
Main Methods:
- Distribution of a homogeneous 124Sb solution to eight participating laboratories.
- Measurement of photon emission intensities in both absolute and relative terms by six laboratories.
- Compilation and analysis of results, including previously published data.
Main Results:
- A consistent decay scheme for 124Sb was established based on the combined results.
- The study demonstrated that activity measurement problems were not attributable to uncertainties in the decay scheme data.
- Agreement was observed among the participating laboratories regarding photon emission intensity measurements.
Conclusions:
- The established decay scheme for 124Sb is reliable and consistent.
- Discrepancies in previous activity measurements of 124Sb are likely due to factors other than decay scheme inaccuracies.
- The international exercise successfully validated measurement techniques and contributed to improved metrology for 124Sb.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...