Minimum contact time and concentration of sodium hypochlorite required to eliminate Enterococcus faecalis
Related Experiment Video
Updated: Jun 16, 2026

Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Bonnie Retamozo1, Shahrokh Shabahang, Neal Johnson
1Department of Endodontics, School of Dentistry, Loma Linda University, Loma Linda, California 92350, USA.
Introduction:
The purpose of this investigation was to determine the concentration of sodium hypochlorite and the irrigation time required to disinfect dentin cylinders infected with Enterococcus faecalis.
Methods:
Four hundred fifty dentin cylinders (5 mm in diameter and 4 mm in height) with a lumen (2-3 mm in width) were prepared from freshly extracted bovine incisors. The cementum and predentin were then removed. The tubules were opened by using a 4-minute application with 17% ethylenediaminetetraacetic acid and 5.25% NaOCl and then exposed to E. faecalis (ATCC 4082) for 3 weeks in brain-heart infusion broth. The cylinders were then divided into 3 groups, and a 1.3%, 2.5%, or 5.25% concentration of NaOCl was applied in 5-, 10-, 15-, 20-, 25-, 30-, 35-, and 40-minute intervals for a total of 30 subgroups including positive and negative controls. Each test sample was placed into a tube of 2 mL brain-heart infusion broth and incubated for 72 hours. Absence of turbidity demonstrated no bacterial growth, whereas turbidity indicated presence of remaining viable bacteria.
Results:
The most effective irrigation regimen was 5.25% at 40 minutes, whereas irrigation with 1.3% and 2.5% NaOCl for this same time interval was ineffective in removing E. faecalis from infected dentin cylinders.
Conclusions:
High concentration and long exposure to NaOCl are needed for elimination of E. faecalis contaminated dentin.