Related Experiment Video
Updated: Mar 30, 2026

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF
Published on: October 17, 2025
Inter- and intraobserver variability in the postoperative evaluation of transpedicular stabilization: computed
Stephan W Tohtz1, Patrick Rogalla, Matthias Taupitz
1Department of Orthopedics, Charité-Universitaetsmedizin, 10117 Berlin, Germany. stephan.tohtz@charite.de
Background Context:
Computed tomography (CT) represents the state of the art for the postoperative verification of the implant position after transpedicular stabilizations. Magnetic resonance imaging (MRI) has not challenged the CT, yet, because of susceptibility artifacts but would be favorable as a diagnostic tool for its excellent soft-tissue qualities.
Purpose:
A study that analyzed if an artifact-reduced MRI could overcome this problem and provide sufficient data for the postoperative assessment was conducted.
Study Design:
The study design was a radiologic comparison of CT and MRI techniques evaluating pedicle screw placement after spinal fusion.
Patient Sample:
Fifty consecutive patients were given an MRI and a CT after a transpedicular stabilization surgery. Thirty-eight patients suffered from degenerative spinal disorders; three surgeries had become necessary because of spondylodiscitis, eight patients suffered from metastatic vertebrae destruction, and one patient experienced a fracture.
Outcome Measures:
Any contact of a malpositioned pedicle screw with the dura and/or radicular structures was identified as an implant-associated complication and was compared with postoperative clinical patient findings.
Methods:
In total, 338 pedicular screws were analyzed in regard to their intrapedicular position. The double-blind evaluation of MRI and CT data was carried out by two radiologists and two spine surgeons. Accuracy of the CT analysis was calculated based on the interobserver agreement of 100%. Magnetic resonance imaging accuracy was calculated.
Results:
The interobserver accuracy of the CT data amounted to a median of 89.8% and in the MRI data of 86.7%. Intraobserver comparisons showed a significant difference between CT and magnetic resonance evaluations in one observer (kappa=0.293). In all other observers, the results were concordant with kappa values from kappa=0.328 to kappa=0.702. There was a high degree of agreement regarding the diagnosis of malpositioned pedicle screw and corresponding clinical symptoms between both techniques.
Conclusions:
The presented data show that artifact-reduced MRI is equivalent to CT imaging in the postoperative evaluation of titanium spinal rod-screw systems. We therefore conclude that MRI should be considered as an alternative tool for the golden standard CT for postoperative imaging controls for its advantages in soft-tissue analysis.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...