Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Robust Automated Mouse Micro-CT Segmentation Using Swin UNEt TRansformers.

Bioengineering (Basel, Switzerland)·2025
Same author

Firearm Injury, It's Not Just Physical: The Adverse Impact on Patient-Reported Socioeconomic, Mental Health, and Quality-of-Life Outcomes.

The American surgeon·2024
Same author

Exploring Automated Contouring Across Institutional Boundaries: A Deep Learning Approach with Mouse Micro-CT Datasets.

ArXiv·2024
Same author

Utility of computed tomography reconstructed thoracolumbar spinal imaging in blunt trauma.

The journal of trauma and acute care surgery·2023
Same author

LncRNA MALAT1 increases the stemness of gastric cancer cells via enhancing SOX2 mRNA stability.

FEBS open bio·2019
Same author

Growth-differentiation factor-15 predicts adverse cardiac events in patients with acute coronary syndrome: A meta-analysis.

The American journal of emergency medicine·2019
Same journal

Enhancing Volumetric Imaging in Linear-Array Photoacoustic Tomography: multiview fusion with deep learning.

IEEE transactions on bio-medical engineering·2026
Same journal

Robust Rule-based Heuristic Assistance Strategy for a Semi-Active Shoulder Exoskeleton Used in Overhead Work.

IEEE transactions on bio-medical engineering·2026
Same journal

Highly Accelerated 1-mm Isotropic 3D Chemical Exchange Saturation Transfer MRI Using Wave-Co-CAIPI at 5 Tesla.

IEEE transactions on bio-medical engineering·2026
Same journal

Systematic Evaluation of Hip Exoskeleton Assistance Parameters for Enhancing Gait Stability During Ground Slip Perturbations.

IEEE transactions on bio-medical engineering·2026
Same journal

SleepConFormer: A Single-Channel EEG Framework for Sleep Staging and Consciousness Assessment in Patients with Disorders of Consciousness.

IEEE transactions on bio-medical engineering·2026
Same journal

Modeling Partial and Total Support of Left Ventricular Assist Device for Discrete Hemodynamic Control Framework.

IEEE transactions on bio-medical engineering·2026
See all related articles

Related Experiment Video

Updated: Jun 16, 2026

Flexible Measurement of Bioluminescent Reporters Using an Automated Longitudinal Luciferase Imaging Gas- and Temperature-optimized Recorder (ALLIGATOR)
10:33

Flexible Measurement of Bioluminescent Reporters Using an Automated Longitudinal Luciferase Imaging Gas- and Temperature-optimized Recorder (ALLIGATOR)

Published on: December 13, 2017

Differential evolution approach for regularized bioluminescence tomography.

Alexander Cong1, Wenxiang Cong, Yujie Lu

  • 1Department of Electrical and Computer Engineering,Virginia Polytechnic Institute and State University, Blacksburg, VA 24060, USA.

IEEE Transactions on Bio-Medical Engineering
|February 23, 2010
PubMed
Summary
This summary is machine-generated.

This article presents a new computational method to improve the accuracy of 3D bioluminescence imaging. By incorporating prior knowledge about the number of light sources, the researchers developed an algorithm that provides more reliable reconstructions of light-emitting probes in complex biological tissues.

Keywords:
inverse source problemoptical imagingstochastic optimization3D reconstruction

Frequently Asked Questions

More Related Videos

Bioluminescence-Based Tumor Quantification Method for Monitoring Tumor Progression and Treatment Effects in Mouse Lymphoma Models
07:12

Bioluminescence-Based Tumor Quantification Method for Monitoring Tumor Progression and Treatment Effects in Mouse Lymphoma Models

Published on: July 7, 2016

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

Related Experiment Videos

Last Updated: Jun 16, 2026

Flexible Measurement of Bioluminescent Reporters Using an Automated Longitudinal Luciferase Imaging Gas- and Temperature-optimized Recorder (ALLIGATOR)
10:33

Flexible Measurement of Bioluminescent Reporters Using an Automated Longitudinal Luciferase Imaging Gas- and Temperature-optimized Recorder (ALLIGATOR)

Published on: December 13, 2017

Bioluminescence-Based Tumor Quantification Method for Monitoring Tumor Progression and Treatment Effects in Mouse Lymphoma Models
07:12

Bioluminescence-Based Tumor Quantification Method for Monitoring Tumor Progression and Treatment Effects in Mouse Lymphoma Models

Published on: July 7, 2016

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

Area of Science:

  • Biomedical imaging research within differential evolution optimization
  • Computational physics and inverse problem theory

Background:

Researchers often struggle to accurately map light sources within deep biological tissues using non-invasive imaging techniques. This specific inverse problem remains notoriously difficult due to the scattering nature of light. Prior research has shown that standard reconstruction models frequently produce unstable or nonunique results. That uncertainty drove the need for improved mathematical frameworks to handle measurement noise effectively. Optical parameter mismatches further complicate the recovery of precise source locations and intensities. No prior work had resolved these instabilities without introducing significant computational overhead or losing spatial resolution. This gap motivated the development of a more robust approach for bioluminescence tomography. The current study addresses these limitations by integrating source count information into the reconstruction process.

Purpose Of The Study:

The aim of this study is to introduce a regularized reconstruction algorithm for bioluminescence tomography. This work addresses the inherent ill-posed nature of the inverse source problem in 3D imaging. The researchers seek to improve the accuracy and reliability of localizing bioluminescent probes within biological tissues. They specifically investigate how incorporating prior knowledge of the number of sources can stabilize the reconstruction process. This motivation stems from the common occurrence of nonunique solutions and aberrant results in existing models. The team intends to overcome challenges posed by measurement noise and optical parameter mismatches. By developing a differential evolution-based approach, they provide a new mechanism for solving this complex optimization task. The study ultimately seeks to validate this novel method through comprehensive numerical, phantom, and animal experiments.

Main Methods:

The review approach involves developing a regularized model that incorporates source count information into the reconstruction process. Investigators utilize a stochastic optimization strategy to solve the resulting inverse problem efficiently. This design focuses on identifying both the spatial coordinates and the emission intensities of light sources. The team implements the algorithm using a population-based search technique to navigate complex solution spaces. They evaluate the performance of this framework through a series of controlled numerical simulations. Furthermore, the researchers conduct physical phantom experiments to test the algorithm against real-world measurement noise. They also apply the method to in vivo mouse studies to demonstrate practical utility. This systematic validation ensures that the reconstruction remains accurate despite potential optical parameter mismatches.

Main Results:

Key findings from the literature indicate that the proposed algorithm achieves high accuracy in localizing bioluminescence sources across all tested scenarios. The researchers report that incorporating source count information effectively stabilizes the reconstruction process. This approach consistently outperforms traditional methods when dealing with significant measurement noise. The data show that the algorithm maintains reliability even in the presence of optical parameter mismatches. Numerical simulations confirm that the method successfully recovers source locations with minimal spatial error. Phantom studies demonstrate that the intensity quantification remains precise under various experimental conditions. In vivo mouse experiments reveal that the technique provides stable reconstructions in complex biological tissues. The results collectively highlight the effectiveness of the differential evolution-based strategy for solving this inverse problem.

Conclusions:

The authors propose that their algorithm significantly enhances the reliability of source localization in complex environments. Synthesis and implications suggest that incorporating source count data stabilizes the underlying inverse problem effectively. This method demonstrates superior performance across numerical simulations and physical phantom experiments compared to traditional techniques. The researchers indicate that their approach successfully mitigates errors caused by optical parameter mismatches. Their findings imply that this strategy provides a viable pathway for more accurate quantitative imaging in small animal models. The study confirms that differential evolution offers a robust framework for solving non-convex optimization tasks in tomography. Future applications may benefit from the improved precision achieved through this regularized model. The evidence supports the utility of this approach for advancing bioluminescence imaging capabilities in biomedical research.

The researchers propose a differential evolution-based algorithm that incorporates prior knowledge of the number of bioluminescence sources. This integration stabilizes the inverse problem, allowing for more accurate and reliable determination of both the spatial coordinates and the emission strengths of the light-emitting probes.

The authors utilize differential evolution, a stochastic population-based optimization technique. This tool is chosen for its ability to navigate complex, non-convex search spaces, which are typical in tomography problems where traditional gradient-based methods might become trapped in local minima or fail to converge.

The authors state that knowledge of the number of sources is necessary to stabilize the ill-posed inverse problem. Without this constraint, the model produces nonunique solutions and aberrant reconstructions, particularly when faced with measurement noise or inaccuracies in the assumed optical parameters of the tissue.

The researchers employ numerical simulations, physical phantom experiments, and in vivo mouse studies to validate their approach. These diverse data types allow for a comprehensive assessment of the algorithm's performance under varying levels of complexity, noise, and biological tissue heterogeneity.

The team measures the accuracy of source localization and the precision of intensity quantification. These metrics are compared against traditional reconstruction methods to demonstrate that their regularized approach yields more consistent results in the presence of optical parameter mismatches and measurement noise.

The authors suggest that their regularized model provides a robust solution for bioluminescence tomography. They imply that this framework effectively addresses the challenges of non-uniqueness and instability, offering a more reliable tool for researchers quantifying probe distributions in 3D biological environments.