Related Experiment Video
Updated: Jun 16, 2026

Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Short-term outcomes with the use of bioprosthetics for the management of parastomal hernias
1Department of Surgery, University of South Alabama, Mobile, Alabama, USA. nellis@usouthal.edu
Purpose:
This study was undertaken to determine the safety and short-term outcomes using bioprosthetics for the management of parastomal hernias.
Methods:
A retrospective review of prospectively collected data for all of the patients who underwent repair of a parastomal hernia was conducted.
Results:
Between April 2004 and September 2007, 20 consecutive patients had 22 parastomal hernias repaired through a midline incision using a bioprosthetic with the stoma entering the abdomen lateral to the graft. A colostomy was present in 17 patients; an ileostomy was present in 3 patients. All of the patients had parastomal hernia-related complications. Postoperatively there were no infections of the midline wound or the prosthetic, and none of the grafts were removed. There were 4 seromas (40%) that required aspiration in the 10 procedures performed before the routine placement of a drain. No incisional hernias have developed in the midline wound. There have been 2 (9%) recurrent parastomal hernias on physical examination at a median follow-up of 18 months (range, 12-54).
Conclusions:
These data suggest that bioprosthetics are safe and are effective in the short term for the repair of parastomal hernias.