Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Short wavelength infrared frequency conversion in ultra-compact fiber device
J M Chavez Boggio1, S Zlatanovic, F Gholami
1University of California, San Diego, La Jolla, CA 92093, USA. jmchavez@ece.ucsd.edu
Optics Express
|February 23, 2010
Summary
Millimeter-scale highly nonlinear fiber coils show minimal loss above 3.5mm radius. Smaller coils cause significant loss beyond 2200nm, impacting short-wave infrared applications.
Area of Science:
- Optics and Photonics
- Materials Science
Background:
- Highly nonlinear optical fibers (HNLF) are crucial for nonlinear optical processes.
- Understanding bending losses in HNLF is essential for device miniaturization and performance.
Purpose of the Study:
- To experimentally investigate the linear and nonlinear characteristics of millimeter-scale HNLF devices.
- To analyze the impact of coil diameter on macro-bending and micro-bending losses.
- To demonstrate a tunable short-wave infrared source using a compact HNLF module.
Main Methods:
- Experimental characterization of HNLF coils with varying radii (≥3.5 mm and <3.5 mm).
- Spectral analysis of radiation loss in the 2000-2400 nm range.
- Construction and testing of a tunable short-wave infrared (SWIR) source.
Main Results:
- Macro-bending induced radiation loss is negligible for coils with radius >3.5 mm up to 2400 nm.
- For smaller coil diameters (<3.5 mm), macro-bending losses exceed micro-bending losses beyond 2200 nm.
- An efficient nonlinear conversion from 1.26 to 2.2 µm was achieved using a coin-sized fiber module.
Conclusions:
- Coil diameter is a critical parameter for managing bending losses in HNLF devices.
- Miniaturized HNLF modules can enable efficient SWIR light generation.
- These findings are relevant for developing compact nonlinear optical devices.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
IR Frequency Region: Fingerprint Region
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
The...
IR Frequency Region: X–H Stretching
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in the 3500–3100 cm−1 range. Even though both O−H and N−H bonds vibrate at a similar...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
IR Absorption Frequency: Hybridization
Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...