CCD detectors for molecular absorption spectrophotometry. A theoretical and experimental study on characteristics and
Javier Galbán1, Susana de Marcos, Isabel Sanz
1Departamento de Química Analítica, Facultad de Ciencias, Universidad de Zaragoza, 50009-Zaragoza, Spain.
Abstract:
Uncertainty in charge-coupled devices (CCDs) as UV-vis spectrophotometric detectors is studied here considering that it highly affects the limit of detection of analytical methods. Opposite to photomultiplier-type detectors (PMDs) and diode-array detectors (DADs), where uncertainty is mainly dependent on the photonic signal (shot noise), in CCD detectors uncertainty may come from both independent and dependent effects upon the photonic signal. Shot noise is specially important for high photonic signals in the detector (those for low absorbances) while the uncertainty that is independent of the signal is specially important for low photonic signals in the detector (those for high absorbances). That is, the main source of uncertainty is different depending on the value of the experimental measurement. On the other hand, temperature does not practically affect absorbance measurements, though it is very important for emission measurements (fluorescence, Raman, scattering, etc.). Mathematical equations for uncertainty are proposed with excellent fittings to the experimental data. The equation parameters can be experimentally determined from non-linear regression analysis and used to characterize spectrometers or to test their performance. In order to help buyers and users, some recommendations are finally given considering, among others, cooling, slit, attenuator or fiber optic assemblies.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
UV–Vis Spectrometers
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...