Non-contact, Label-free Monitoring of Cells and Extracellular Matrix using Raman Spectroscopy
Published on: May 29, 2012
Thermal monitoring: Raman spectrometer system for remote measurement of cellular temperature on a microscopic scale
1Neural Engineering Program of the Huntington Medical Research Institutes.
Abstract:
A simple setup is demonstrated for remote temperature monitoring of water, water-based media, and cells on a microscopic scale. The technique relies on recording changes in the shape of a stretching band of the hydroxyl group in liquid water at 3,100-3,700 cm(-1). Rather than direct measurements in the near-infrared (IR), a simple Raman spectrometer setup is realized. The measured Raman shifts are observed at near optical wavelengths using an inverted microscope with standard objectives in contrast to costly near-IR elements. This allows for simultaneous visible inspection through the same optical path. An inexpensive 671-nm diode pump laser (< 100 mW), standard dichroic and lowpass filters, and a commercial 600-1,000 nm spectrometer complete the instrument. Temperature changes of 1 degrees C are readily distinguished over a range consistent with cellular processes (25-45 degrees C) using integration times below 10 s. Greatly improved sensitivity was obtained by an automated two-peak fitting procedure. When combined with an optical camera, the instrument can be used to monitor changes in cell behavior as a function of temperature without the need for invasive probing. The instrument is very simple to realize, inexpensive compared with traditional Raman spectrometers and IR microscopes, and applicable to a wide range of problems in microthermometry of biological systems. In a first application of its kind, the instrument was used to successfully determine the temperature rise of a cluster of H1299 derived human lung cells adhered to polystyrene and immersed in phosphate-buffered saline (PBS) under exposure of RF millimeter wave radiation (60 GHz, 1.3, 2.6, and 5.2 mW/mm2).
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...