Comparison of Omega Wave System and Polar S810i to detect R-R intervals at rest
E Parrado1, M A García, J Ramos
1Universitat Autonoma de Barcelona, Laboratory of Sport Psychology, Bellaterra, Spain. eva.parrado@uab.cat
Abstract:
The present study was performed to compare R-R interval data and heart rate variability indices obtained from the Polar S810i and the Omega Wave Sport System for a total of 96 adults in a supine position. Data were simultaneously recorded with the Polar S810i and the Omega Wave Sport System and processed by unique software. Bland-Altman analysis for the R-R intervals shows minimal bias for free and paced breathing. No significant differences were observed for heart rate variability indices derived from the signal from both devices, except for the power of the high frequency band and the acceleration changes index during either free or paced breathing. Coefficients of correlations were all above 0.96. These data suggest that both systems are valid to record R-R interval signals and to obtain a valid analysis of heart rate variability. However, Omega Wave Sport System enables data to be collected without any artifacts making the analysis of heart rate variability easier than the analysis of Polar S810i. Nevertheless, Polar S810i continues to be more practical in clinical and applied situations due to the affordability of the device.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...