Related Experiment Video
Updated: Jun 15, 2026

Endoscopic Vacuum Therapy for the Treatment of Anastomotic Leakage after Total Gastrectomy with Esophagojejunostomy
Published on: August 22, 2025
Leaks and endoscopic assessment of break of integrity after NOTES gastrotomy: the LEAKING study, a prospective,
Field F Willingham1, Brian G Turner, Denise W Gee
1Department of Medicine, Gastrointestinal Unit, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, USA.
Background:
Gastric leak testing after natural orifice transluminal endoscopic surgery (NOTES) gastrotomy closure may help reduce the risk of leaks after transgastric procedures.
Objective:
To develop a novel endoscopy-based system to determine the presence of a leak after NOTES gastrotomy and to compare this system prospectively with radiographic leak testing.
Design:
Prospective, randomized, controlled trial.
Setting:
Academic Medical Center laboratory.
Subjects:
Fifty swine.
Intervention:
During the pretrial phase, an endoscopic system for the measurement of intragastric pressure was developed. In the trial phase, swine with a NOTES gastrotomy were randomized to endoscopic versus radiographic leak testing. If a leak was demonstrated, the gastrotomy was reclosed by using a second-generation prototype T-anchor system. The primary outcome was leak detection after gastrotomy closure. The secondary outcome variables included necropsy findings, peritoneal fluid analysis, histologic examination, and clinical outcome.
Results:
Fourteen swine were included in the pretrial phase and 36 in the randomized trial. Swine were survived for a mean of 9 days postoperatively. Endoscopic pressure monitoring demonstrated a reproducible change in intragastric pressure with insufflation; r = 0.735, P = .001 and r = 0.769, P < or = .000 for the total and maximum pressures, respectively. Post-peritoneoscopy, there was a detectable and significant decrease in the mean total and mean maximum pressures versus baseline (P = .006 and P = .009). There was no significant difference between the radiologic and endoscopic arms in leak detection rate (4/18 vs 3/18, respectively, P = .500). Clinical outcomes and mean weight gain were equivalent. There was 1 operative abdominal wall injury and no deaths.
Limitations:
Animal study.
Conclusion:
Endoscopic pressure monitoring was reproducible, demonstrated the presence of gastric leak, and was as reliable as contrast-based radiographic leak testing.
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
Peptic Ulcer Disease V: Surgical Management and Nursing Care
Surgical Interventions for Peptic Ulcer Disease
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Endoscopic Procedures V: ERCP
Patient...