Quantitative analysis of adhesive resin in the hybrid layer using Raman spectroscopy
Yuan Zou1, Steven R Armstrong, Julie L P Jessop
1Department of Chemical and Biochemical Engineering, University of Iowa, Iowa City, Iowa 52242, USA.
None:
The objective was to determine absolute molar concentration of adhesive resin components in the hybrid layer by establishing methods based on Raman spectroscopy fundamentals. The hybrid layer was treated as a three-component system consisting of collagen and an adhesive resin containing two monomers. Adhesive standard specimens and Raman peak area ratios obtained with a 785 nm excitation wavelength were used to construct separate calibration curves for comonomer relative molar concentration and Bis-GMA absolute molar concentration. As collagen and water had no measurable peaks in the fingerprint region, a dilution coefficient K(j) was defined to describe their impact on Raman peak area and to calculate HEMA absolute molar concentration. Methodology was validated using an analogous system containing acetone/ethanol/water. The absolute molar concentration of Bis-GMA and HEMA decreased 87% and 83%, respectively, from the top quarter to the middle of the hybrid layer. Additionally, less Bis-GMA penetrated the hybrid layer than HEMA, as indicated by the approximately 20% decrease in comonomer molar concentration ratio between the adhesive resin layer and the top half of the hybrid layer. Lack of complete monomer infiltration will further challenge dentin-adhesive bond longevity. (c) 2010 Wiley Periodicals, Inc. J Biomed Mater Res, 2010.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...