Related Experiment Video
Updated: Jun 15, 2026

A Semi-Automated and Reproducible Biological-Based Method to Quantify Calcium Deposition In Vitro
Published on: June 2, 2022
Measurement of 25-hydroxyvitamin D in the clinical laboratory: current procedures, performance characteristics and
A M Wallace1, S Gibson, A de la Hunty
1Department of Clinical Biochemistry, Macewen Building, Royal Infirmary, Glasgow G4 0SF, UK. alanm.wallace@nhs.net
Abstract:
In this review we describe procedures, performance characteristics and limitations of methods available for the measurement of 25-hydroxyvitamin (25OHD) since the year 2000. The two main types of methods are competitive immunoassay and those based on chromatographic separation followed by non-immunological direct detection (HPLC, LC-MS/MS). Lack of a reference standard for 25OHD has, until recently, been a major issue resulting in poor between-method comparability. Fortunately this should soon improve due to the recent introduction of a standard reference material in human serum (SRM 972) from the National Institute of Standards and Technology (NIST). For immunoassay, specificity can be an issue especially in relation to the proportion of 25OHD2 that is quantified whereas HPLC and LC-MS/MS methods are able to measure the two major vitamin D metabolites 25OHD2 and 25OHD3 independently. HPLC and LC-MS/MS require more expensive equipment and expert staff but this can be offset against lower reagent costs. Increasingly procedures are being developed to semi-automate or automate HPLC and LC-MS/MS but run times remain considerably longer than for immunoassays especially if performed on automated platforms. For most HPLC and LC-MS/MS methods extraction and procedural losses are corrected for by the inclusion of an internal standard which, in part, may account for higher results compared to immunoassay. In general precision of immunoassay, HPLC and LC-MS/MS are comparable and all have the required sensitivity to identify severe vitamin D deficiency. Looking to the future it is hoped that the imminent introduction of a standard reference method (or methods) for 25OHD will further accelerate improvements in between method comparability.
Related Concept Videos
Role of Skin in Vitamin D Synthesis
The solar UV B rays (290-315 nm) are absorbed by the skin, and 7-dehydrocholesterol (provitamin D3) photolyzes it to previtamin D3, which undergoes a rapid transformation to vitamin D3(cholecalciferol).
Therapeutic Drug Monitoring: Drug Analysis Methods
Clinically Relevant Drug Product Specifications: Methods of Establishment
Measurement of Bioavailability: Pharmacodynamic Methods
Automated Microbial Diagnostics