Related Experiment Video
Updated: Jun 15, 2026

Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
Photoacoustic spectroscopy as a tool for determination of food dyes: comparison with first derivative
T M Coelho1, E C Vidotti, M C Rollemberg
1Departamento de Física, Universidade Estadual de Maringá, Av. Colombo, 5790 Maringá, PR - 87020-900, Brazil.
Abstract:
Photoacoustic spectroscopy (PAS) was applied as a method to quantify dyed food samples, and was compared with First Derivative Spectrophotometry (FDS). The dyes Brilliant Blue (B), Sunset Yellow (S) and Tartrazine (T), which are common food additives, were employed for the comparisons. Polyester-type Polyurethane (PU) foam was used for extraction of the dyes from a solution containing the food matrix. For the spectrophotometric determinations, the adsorbed dyes were recovered by using dimethylformamide. The PAS measurements were carried out directly on the PU foam. The PAS method showed greater sensitivity, with detection limits of 0.028 mg L(-1) and 0.086 mg L(-1) for S and T, respectively, in the S+T mixture, and of 0.012 mg L(-1) and 0.068 mg L(-1) for B and T, respectively, in the B+T mixture. The values of relative error obtained for all the dyes were small: approximately 0.3-3.6% for the spectrophotometer, and approximately 0.1-2.9% for the PAS method. The PAS technique can be applied to the determination of the selected dyes in commercial food products, with some advantages: it reduces the number of analysis steps, it is a "green" method with less chemical waste, a minimal sample amount is needed, and it is non-destructive.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...