Related Experiment Video
Updated: Jun 15, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Optimization and comparison of HPLC and RRLC conditions for the analysis of carbonyl-DNPH derivatives
Soraya de M Ochs1, Maíra Fasciotti, Renata P Barreto
1Programa de Pós-Graduação em Química, Instituto de Química, Universidade Federal Fluminense, Outeiro de São João Batista, s/n, 24020-141 Centro, Niterói, RJ, Brazil.
Abstract:
Analytical conditions for the analysis of 15 carbonyl-DNPH derivatives were optimized and compared by high performance liquid chromatography (HPLC) and rapid resolution liquid chromatography (RRLC). Binary, ternary and quaternary mixtures of acetonitrile, isopropanol, methanol, tetrahydrofuran and water were evaluated under RRLC conditions employing a Zorbax Eclipse Plus C18 (50 mm x 4.6 mm x 1.8 microm) column and a Zorbax Eclipse Plus C18 (50 mm x 2.1 mm x 1.8 microm) column. The optimized conditions obtained employing the two RRLC columns were compared with those obtained using a Supelcosil C18 (250 mm x 4.6 mm x 5 microm; Supelco) that is designed for HPLC separation of DNPH derivatives. Chromatograms run with a Zorbax Eclipse Plus C18 (50 mm x 2.1 mm x 1.8 microm) column and a mobile phase composed of isopropanol, methanol, tetrahydrofuran and water led to the best separation conditions considering reduced analysis time (approximately 6 min per run), solvent consumption rate (approximately 2 mL per run) and resolution of propanone, acrolein and propionaldehyde hydrazones. Quantification limits and linear ranges were adequate for direct application of EPA TO-11 conditions in all sets of RRLC and HPLC conditions. The analytical method was applied in the determination of carbonyl compounds (CCs) in Niterói City, RJ, Brazil in samples that were collected during periods of 2h. Formaldehyde (8.22-9.78 ppbv) predominated in all periods followed by acetaldehyde (1.77-3.99ppbv) and propanone (1.89-3.26 ppbv). Heavy CCs such as butyraldehyde and benzaldehyde were also detected in most samples. Total CCs varied along the studied day. The obtained results showed that RRLC can be applied to CCs determination without any change in the conditions of sample preparation of the Method EPA TO-11.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
