Delivered dose and regional distribution of aerosolized pentamidine using different delivery systems
J S Ilowite1, M I Baskin, M S Sheetz
1Pulmonary Division, St. Luke's/Roosevelt Hospital Center, New York.
Abstract:
Aerosolized pentamidine has gained acceptance as a form of treatment for the prevention of Pneumocystis carinii pneumonia. However, different studies have used different delivery systems, making comparison of results difficult. This study was designed to determine the dose to the lung, regional distribution, extrapulmonary deposition, and side effects using four different delivery systems: the Respirgard II, the Aero Tech II, the Portasonic, and the Fisoneb. Ten homosexual subjects who were infected with HIV virus were studied. Particle size, as determined by cascade impaction, varied among nebulizers. Mass median aerodynamic diameter was 0.90 mu for the Respirgard II, 1.30 mu for the Aero Tech II, 1.40 mu for the Portasonic, and 3.90 mu for the Fisoneb. Subjects inhaled a solution containing 60 mg pentamidine in 3 ml of sterile water, and 1 ml of 99mTc bound to human serum albumin for each nebulizer system. Regional distribution was determined by comparing each deposition scan obtained by a posteriorly positioned gamma camera to the subjects' equilibrium xeon scan. The deposition scan was used to quantitate lung dose and extrapulmonary deposition. Marked differences were seen among delivery systems. Dose to the lung varied fivefold. The deposition in the lung, expressed as a percentage of the amount placed in the nebulizer, was 5.3 percent in the Respirgard II, 15.7 percent in the Aero Tech II, 17.30 percent in the Portasonic, and 26.4 percent in the Fisoneb (p less than 0.0001 by ANOVA). Wide differences in extrapulmonary deposition and side effects were noted among nebulizers (Fisoneb greater than Portasonic, Aero Tech II greater than Respirgard II). Regional distribution in the lung as measured by the AI, also showed differences, with the Respirgard having the most homogeneous distribution of aerosol (Respirgard greater than Portasonic, Aero Tech greater than Fisoneb). Regional distribution and extrapulmonary deposition varied in a manner consistent with the particle size of the nebulizers. These data should provide a framework for the comparison and design of future clinical studies using these delivery systems.
Related Concept Videos
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
Inhaled Medications
Drug Delivery: Overview
Enteral delivery involves administering drugs directly through swallowing, sublingual placement, or buccal application. Orally administered drugs predominantly navigate the gastrointestinal...
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs through the...
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices