Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Applications of EMF Measurements01:26

Applications of EMF Measurements

Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and the equilibrium...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Consistency of feed efficiency ranking and mechanisms associated with inter-animal variation among growing calves.

Journal of animal science·2018
Same author

First experiments with the negative ion source NIO1.

The Review of scientific instruments·2016
Same author

Molecular and morphological variation in saddled fathead sculpins (Psychrolutidae: Cottunculus) of the north-east Atlantic Ocean, with a synonymy of three species.

Journal of fish biology·2014
Same author

Short communication: effect of pomegranate-residue supplement on Cryptosporidium parvum oocyst shedding in neonatal calves.

Journal of dairy science·2014
Same author

Time required to determine performance variables and production efficiency of lactating dairy cows.

Journal of dairy science·2014
Same author

Installation of a versatile multiaperture negative ion source.

The Review of scientific instruments·2014
Same journal

Compressed multi-scale entropy and its application in mechanical fault diagnosis.

The Review of scientific instruments·2026
Same journal

Bidirectional drive and multi-resolution adjustment across frequency bands in inertial impact piezoelectric motors via multimodal resonant vibration.

The Review of scientific instruments·2026
Same journal

A magnetic field sensor based on flaky Terfenol-D material and dual fiber grating.

The Review of scientific instruments·2026
Same journal

A novel E-field eight-way cavity combiner for high-power S-band applications.

The Review of scientific instruments·2026
Same journal

Constant radius blade spring suspended bench for vibration isolation.

The Review of scientific instruments·2026
Same journal

Qualification of infrared optical fibers and emitters for a spectrometer for in situ planetary exploration: Results from the TRIS (TRansmission and Illumination System) project.

The Review of scientific instruments·2026
See all related articles

Related Experiment Video

Updated: Jun 15, 2026

Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
08:59

Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System

Published on: May 22, 2020

Portable emittance measurement device.

D Liakin1, D Seleznev, A Orlov

  • 1Institute for Theoretical and Experimental Physics, Moscow 117218, Russia.

The Review of Scientific Instruments
|March 3, 2010
PubMed
Summary
This summary is machine-generated.

A portable device for measuring particle beam emittance was developed at the Institute for Theoretical and Experimental Physics (ITEP). This device utilizes both "pepper-pot" and "two slits" methods for accurate beam characterization.

More Related Videos

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
06:43

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band

Published on: May 2, 2018

Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe
09:34

Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe

Published on: December 4, 2016

Related Experiment Videos

Last Updated: Jun 15, 2026

Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
08:59

Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System

Published on: May 22, 2020

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
06:43

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band

Published on: May 2, 2018

Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe
09:34

Implementation of Portable Emissions Measurement Systems (PEMS) for the Real-driving Emissions (RDE) Regulation in Europe

Published on: December 4, 2016

Area of Science:

  • Physics
  • Accelerator Physics
  • Beam Diagnostics

Background:

  • Accurate measurement of particle beam emittance is crucial for accelerator performance.
  • Existing emittance measurement techniques can be complex and non-portable.

Purpose of the Study:

  • To develop a portable device for emittance measurements.
  • To implement both "pepper-pot" and "two slits" methods in a single device.

Main Methods:

  • A portable emittance measurement device was designed and constructed.
  • The device incorporates interchangeable "pepper-pot" or "two slits" masks with scintillators.
  • Adjustable pipe length between vacuum chambers allows for optimized angle resolution.

Main Results:

  • The device was successfully tested at the Institute for Theoretical and Experimental Physics (ITEP) ion source test bench.
  • Emittance measurements were performed using both implemented methods.
  • The portable nature of the device facilitates measurements in various experimental setups.

Conclusions:

  • The developed portable device provides a flexible and effective solution for emittance measurements.
  • The dual-method capability enhances its applicability in different beam conditions.
  • This instrument aids in the characterization and optimization of particle beams.