Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Spot on: A Laser Micromachining-Based Approach to Improve Dried Matrix Spot Preparation with Proof-of-Principle Analytical Demonstrations Using Ambient Ionization Mass Spectrometry.

Micromachines·2026
Same author

Preventing chick culling in the poultry industry with a new biomarker for rapid in ovo gender screening.

Scientific reports·2026
Same author

The product of NH<sub>3</sub> loss from gas phase protonated tyrosine.

Physical chemistry chemical physics : PCCP·2026
Same author

Ultra-high throughput mass spectrometry with ultra high-speed separations: differential mobility spectrometry-acoustic ejection mass spectrometry (DAEMS).

Bioanalysis·2025
Same author

High-Throughput Detection and Quantitation of Metal Contamination with Acoustic Ejection Mass Spectrometry.

Journal of the American Society for Mass Spectrometry·2025
Same author

Resonance-Enhanced Multiphoton Ionization Spectrum and Computational Study of 2-Cyclopenten-1-one in Its <i>T</i><sub>1</sub>(<i>n</i>, π*) State.

The journal of physical chemistry. A·2025

Related Experiment Video

Updated: Jun 15, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

Selection and generation of waveforms for differential mobility spectrometry.

Evgeny V Krylov1, Stephen L Coy, John Vandermey

  • 1Sionex Corporation, 8-A Preston Ct., Bedford, Massachusetts 01730, USA. ekrylov@sionex.com

The Review of Scientific Instruments
|March 3, 2010
PubMed
Summary

Differential mobility spectrometry (DMS) uses electric fields for ion separation. This study analyzes how waveform and field strength impact DMS resolution, optimizing generator designs for better chemical detection.

More Related Videos

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
16:40

T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis

Published on: July 31, 2010

Related Experiment Videos

Last Updated: Jun 15, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
11:18

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

Published on: July 11, 2017

T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
16:40

T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis

Published on: July 31, 2010

Area of Science:

  • Analytical Chemistry
  • Spectrometry
  • Physical Chemistry

Background:

  • Differential mobility spectrometry (DMS) is a versatile technique used in various analytical systems, including ion prefilters for API-MS and standalone chemical detectors.
  • DMS performance, specifically ion separation, is critically dependent on the characteristics of the applied asymmetric electric field, known as the DMS separation field, and its waveform.
  • The separation mechanism relies on the alpha dependence, the difference between high and low field ion mobility.

Purpose of the Study:

  • To analyze the relationship between separation waveform parameters and DMS resolution.
  • To investigate feasible separation field generators and their circuit implementations for optimizing DMS performance.
  • To establish relationships connecting ion alpha dependence to DMS separation fields for generator design optimization.

Main Methods:

  • Analysis of ideal and practical DMS separation field waveforms.
  • Evaluation of DMS separation power for common generator types based on waveform parameters.
  • Determination of optimal waveforms for various ion alpha dependences using derived relationships.
  • Validation of theoretical calculations through experimental data comparison.

Main Results:

  • A set of relations was developed to connect ion alpha dependence with DMS separation fields, aiding generator design.
  • The DMS separation power of different generator types was evaluated as a function of waveform parameters.
  • Optimal waveforms were identified for major DMS separation generator types across a range of ion alpha dependences.

Conclusions:

  • The study provides a framework for optimizing DMS separation field generator designs by linking waveform characteristics to resolution.
  • Understanding the interplay between waveform parameters, separation field, and ion properties is crucial for enhancing DMS performance.
  • The findings facilitate the development of more effective DMS systems for chemical detection and identification.