Related Experiment Video
Updated: Jun 15, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
[Biomechanical study and clinical application of cannulated compression screws with across solid frame for
Jian-zheng Zhang1, Tian-sheng Sun, Zhi Liu
1Department of Orthopedic Surgery, Beijing Army General Hospital, Beijing 100700, China.
Objective:
To evaluate the safety and efficiency of treating the senile intertrochanteric fractures with cannulated compression screws (CCS) with across solid frame in femur head via biomechanical tests and clinical application.
Methods:
Biomechanical tests: the fracture model was made in 31-A1.3 style, 6 pairs of flesh and embalmed cadaveric femurs were mechanically tested in a single-limb stance configuration. A material testing machine was used to apply vertical loads onto the femoral head. Both stiffness and reverse turn were recorded. Clinical application: from 1998 to 2006, According to damage control orthopedics (DCO) and American Society of Anesthesiologists (ASA) and the Evans classification, 51 patients received treatment with CCS with across solid flame in femur head. All the cases were followed up for 12 to 36 months (mean: 18 months).
Results:
the differences between two groups in BMD (bone mineral density) were of statistical significance. And tensile rigidity and torsional rigidity of CCS were strong enough to bear weight. The CCS group had a lesser amount of blood loss or transfusion and lower treatment expenses.
Conclusion:
Cannulated compression screw with across solid flame is strong enough to be employed as an effective method to treat aged intertrochanteric hip fractures with the advantages of simple procedure, minimal invasion, stable fixation and weight bearing.