Related Experiment Video
Updated: Jun 15, 2026

15:06
Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
Published on: January 3, 2016
Detector nonlinearity effects on the statistics of a fluctuating signal
Applied Optics
|March 4, 2010
Abstract:
The effect of the detector nonlinearity on the statistics of a fluctuating signal is evaluated. The input signal is assumed to be log-normally distributed, which is of interest in the study of the laser propagation through the turbulent atmosphere. Both detector threshold and saturation effects are taken into account.
Related Concept Videos
Nonlinear Pharmacokinetics: Overview
Nonlinear or dose-dependent pharmacokinetics is a phenomenon that occurs when the pharmacokinetic parameters of certain drugs deviate from linear pharmacokinetics at higher doses. These drugs do not follow the expected first-order kinetics, where the rate of drug elimination is directly proportional to the drug concentration. Instead, they exhibit a nonlinear relationship, which can be attributed to several factors.
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinearity in drug pharmacokinetics is caused by various factors influencing how a drug is absorbed, distributed, metabolized, and excreted. Understanding these nonlinear processes is crucial for predicting drug behavior in the body and optimizing drug dosing regimens.
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Random Error
Random or indeterminate errors originate from various uncontrollable variables, such as variations in environmental conditions, instrument imperfections, or the inherent variability of the phenomena being measured. Usually, these errors cannot be predicted, estimated, or characterized because their direction and magnitude often vary in magnitude and direction even during consecutive measurements. As a result, they are difficult to eliminate. However, the aggregate effect of these errors can be...
Linear Approximation in Frequency Domain
Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
NMR Spectrometers: Resolution and Error Correction
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
¹H NMR: Interpreting Distorted and Overlapping Signals
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...

