Related Experiment Video
Updated: Jun 15, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
[Positron emission tomography 2008 in Germany - results of the query and current status]
J Kotzerke1, L Oehme, O Lindner
1Klinik und Poliklinik für Nuklearmedizin, Universitätsklinikum Dresden, Fetscherstr. 74, 01307 Dresden, Germany. joerg.kotzerke@mailbox.tu-dresden.de
Aim:
The working group on positron emission tomography (PET) of the DGN (German Society of Nuclear Medicine) initiated this first survey to collect and analyse information on the practise of PET in Germany in the year 2008.
Methods:
A questionnaire was sent to PET performing facilities (medical practices, hospitals, university hospitals and others) for retrospective data acquisition. Details regarding the equipment and examination procedures were examined as well as indications and number of studies. In addition, the role of PET within the diagnostic process was evaluated.
Results:
Responses from 65 sites were analysed. Their technical equipment consisted of 77 PET scanners (40 of them were combined PET/CT devices). About 63500 PET studies had been performed with 86% in the field of oncology, 8% in neurology and 3% in cardiology. The radiotracers were labelled with 18F in 91% of the studies, whereas 68Ga was used in 4% and 11C in 3%. The analyses revealed lung tumours as the most investigated tumour entity, followed by malignant lymphoma, tumours of the gastro-intestinal tract and prostate cancer (about 14000, 6000, 5000 and 2000). Corresponding to the new scanners and software procedures, the number of studies with attenuation correction by CT was high (68%) and nearly all studies were reconstructed iteratively (99%). The PET images were analysed quantitatively in the majority of cases (91%). The clinical reports, which included image documentation for the greater part, were posted regularly within 3 days. However, in 70% of the sites electronic transfer possibilities were used additionally to speed up the diagnostic process. The high standard of quality was demonstrated by the fact, that 40 facilities were engaged in a tumour board. Further on, one third of the physicians had gained a PET certification awarded by the DGN.
Conclusion:
Relative to the high general standard of diagnostic instrumentation in Germany, PET is less established, in particular when compared with other industrialised countries such as USA and Switzerland.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...