Related Experiment Video
Updated: Jun 15, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Monte Carlo simulations of the dosimetry of chest tomosynthesis
Angelica Svalkvist1, Lars Gunnar Månsson, Magnus Båth
1Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-41345 Gothenburg, Sweden. angelica.svalkvist@vgregion.se
Abstract:
The aims of this work were to explore the dosimetry of chest tomosynthesis and to determine conversion factors between air kerma-area product (KAP) and the effective dose for different system configurations and patient sizes. Tomosynthesis systems were modelled with different angular intervals and tube voltages for the collection of the projection images as well as different distributions of the total exposure over the projections. The Monte Carlo-based computer software PCXMC developed by STUK (Radiation and Nuclear Safety Authority in Finland) was used to calculate the effective doses for each modelled tomosynthesis system for various patient sizes. The conversion factor between KAP and effective dose was obtained both for the zero-degree projection alone and for the entire tomosynthesis examination for each system configuration and patient size. The results reveal that the conversion factor for the zero-degree projection can be used to estimate the total effective dose from a tomosynthesis examination with acceptable accuracy, leading to an error smaller than 10 % irrespective of the system configuration and patient size. For higher accuracy, conversion factors between the total KAP and the total effective dose that take the angular interval and exposure configuration into account are presented for each system.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...