Related Experiment Video
Updated: Jun 15, 2026

A Novel Use of Three-dimensional High-frequency Ultrasonography for Early Pregnancy Characterization in the Mouse
Published on: October 24, 2017
Real-time three-dimensional ultrasound with Live xPlane imaging assists first-trimester acquisition of a true
1Fetal Medicine Unit, Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China. xiongyi.xiongyi@163.com
Objective:
To determine whether real-time three-dimensional (3D) ultrasound with Live xPlane imaging, which enables the simultaneous display of two real-time high-quality image planes, can assist both operators certified by The Fetal Medicine Foundation (FMF) and non-FMF-certified operators in acquiring a true midsagittal plane in the first trimester.
Methods:
Eight operators, four of them FMF certified (FMF group) and the other four not (non-FMF group), were asked to acquire a fetal image that they believed to represent the true midsagittal plane using real-time 3D ultrasound with Live xPlane imaging as guidance. Each operator was asked to obtain such an image five times from each of five patients. A total of 200 images from 40 patients were obtained and stored for subsequent analysis. All pregnancies were between 11 + 0 and 13 + 6 weeks of gestation. The angle between the falx cerebri and vertical axis (angle of deviation) was then measured by a single operator. A true midsagittal section was defined as an angle of deviation equal to 0 degrees. The angle of deviation and the time taken to acquire each image were compared between FMF and non-FMF groups.
Results:
The median angle of deviation for each operator ranged from 1.2 degrees to 3.4 degrees. There was no significant difference in this angle between those who were FMF certified and those who were not (2.0 degrees vs. 2.2 degrees, P = 0.463). The interquartile range of the angle of deviation was also similar between the FMF- and non-FMF-certified operators. Although the time taken for image acquisition was longer among the non-FMF-certified operators (median, 45.5 s vs. 32.0 s), this difference did not reach statistical significance (P = 0.107).
Conclusion:
Live xPlane imaging can provide a tool to assist the acquisition of a true midsagittal plane and to determine how true a 'midsagittal' plane really is.
More Related Videos
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...