Related Experiment Video
Updated: Jun 15, 2026

Cavernous Nerve Stimulation and Recording of Intracavernous Pressure in a Rat
Published on: April 23, 2018
Tracheal tube cuff pressure depends on the anaesthesiologist's experience. A follow-up study
Magdalena A Wujtewicz1, Wioletta Sawicka, Radosław Owczuk
1Department of Anaesthesiology and Intensive Therapy, Medical University of Gdańsk. magwuj@ang.gda.pl
Background:
Excessive tracheal tube cuff pressure can cause ischemia of the tracheal mucosa, and possible serious complications, such as tracheal stenosis, formation of tracheo-oesophageal fistula or even life-threatening haemorrhage. Inadequate cuff pressure increases the risk of aspiration of gastric contents.
Methods:
The cuff pressures were analysed on the basis of the anaesthesiologists' experience. The results were compared to those obtained during the previous study which had been conducted seven years earlier (2002). The physicians were divided into three groups, according to their experience: group I - less than 2 years of practice; group II--2 to 10 years of practice; and group III--over 10 years of practice. High-volume, low-pressure tubes were used for intubation. The anaesthesiologists were not informed of the planned audit.
Results:
Statistical analysis demonstrated significant differences between cuff pressure readings in the respective study groups. Cuff pressures in group II (p < 0.05) and group III (p < 0.0005) were greater than those in group I. In 2002, no statistically significant differences had been observed between the three groups (p = 0.1156). When comparing results from 2002 and present one differences were observed inside individual groups, concerning group II (p < 0.05) and group III (p < 0.0005).
Conclusion:
There is a tendency to overinflation of endotracheal tube cuffs in all groups. This problem is more common in the group of highly experienced anaesthesiologists, and is more more prevalent at present than in 2002.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

