Management of patient doses and diagnostic reference levels in X-ray radiography in Lithuania
J Ziliukas1, L Krynke, A Urboniene
1Radiation Protection Centre, Kalvariju 153, LT-08221 Vilnius, Lithuania. j.ziliukas@rsc.lt
Abstract:
Management of patient doses and determination of national or local diagnostic reference levels (DRLs) are important parts of a quality control program in X-ray diagnostics. In Lithuania, national DRLs for specific radiographic examinations are comparatively higher than those recommended by the European Commission (EC) and the International Atomic Energy Agency (IAEA). A survey of entrance surface doses (ESDs) was performed to investigate the reasons for exceeding the European and the IAEA DRLs. The first measurements showed that the average ESD for standard patients and for all examinations exceeded DRLs at approximately 25 % of the hospitals. The main problems were the use of low kilovolt technique, the lack of automatic exposure control systems or improper adjustment of them as well as inadequate training of the staff. After corrective actions, the ESD measurements were repeated. The results showed that the average patient doses were reduced almost everywhere. An additional patient dose survey for establishing new DRLs in radiography taking into account the advantages of new equipment to indicate directly the kerma area product (KAP) values was done. The ESD values were calculated from the KAP-values. The data were analysed, and the average and third quartile values were calculated. The new DRLs, in terms of ESDs, were reduced significantly in almost all radiography examinations. They are equal or lower than the IAEA and EC DRLs. Especially at thorax spine LAT, lumbar spine LAT, hip joint AP, pelvis AP and abdomen AP they are half the IAEA DRLs.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Biological Effects of Radiation
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...