Related Experiment Video
Updated: Jun 15, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Assessing PaCO2 in acute respiratory disease: accuracy of a transcutaneous carbon dioxide device
K Perrin1, M Wijesinghe, M Weatherall
1Medical Research Institute of New Zealand, University of Otago Wellington, New Zealand.
Background:
Pulse oximetry non-invasively assesses the arterial oxygen saturation of patients with acute respiratory disease; however, measurement of the arterial partial pressure of carbon dioxide (PaCO(2)) requires an arterial blood gas. The transcutaneous partial pressure of carbon dioxide (PtCO(2) ) has been used in other settings with variable accuracy. We investigated the accuracy of a PtCO(2) device in the assessment of PaCO(2) in patients with asthma and suspected pneumonia attending the emergency department.
Methods:
Patients with severe asthma (FEV(1) < 50% predicted) or suspected pneumonia (fever, cough and respiratory rate >18/min) were enrolled. Subjects were excluded if they had a history of chronic obstructive pulmonary disease or other conditions associated with respiratory failure. Arterial blood gases were taken at the discretion of the investigator according to clinical need, and paired with a simultaneous reading from the PtCO(2) probe.
Results:
Twenty-five patients were studied with one set of data excluded because of poor PtCO(2) signal quality. The remaining 24 paired samples comprised 12 asthma and 12 pneumonia patients. The range of PaCO(2) was 19-64 mmHg with a median of 36.5 mmHg. Bland-Altman analysis showed a mean (SD) PaCO(2) - PtCO(2) difference of -0.13 (1.9) mmHg with limits of agreement of plus or minus 3.8 mmHg (-3.9 to +3.7).
Conclusion:
A PtCO(2) device was accurate in the assessment of PaCO(2) in patients with acute severe asthma and suspected pneumonia when compared with an arterial blood gas. These bedside monitors have the potential to improve patient care by non-invasively monitoring patients with acute respiratory disease at risk of hypercapnia.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Acute Respiratory Failure-III