Tissue oxygenation measured with near-infrared spectroscopy during normobaric and hyperbaric oxygen breathing in healthy subjects
Related Experiment Video
Updated: Jun 15, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Agneta Larsson1, Johan Uusijärvi, Staffan Eksborg
1Department of Physiology and Pharmacology, Section for Anaesthesiology and Intensive Care Medicine, Karolinska Institutet, 171 77 Stockholm, Sweden. agneta.c.larsson@karolinska.se
Abstract:
To evaluate the possibility of using near-infrared spectroscopy (NIRS) to measure tissue oxygenation (StO(2)) during hyperbaric oxygen (HBO) therapy. Nine healthy volunteers (1 female) age 25-37 years, breathed air or oxygen. Tissue oxygenation was measured using NIRS on the thumb. Subjects were blinded to breathing gas. A range of partial pressures of oxygen were administered in 10-min intervals: 21, 101, 21 kPa (compression to 280 kPa), 59, 280, 59 (decompression), 21 kPa. Data were averaged over last 5 min at each pressure. When switching from air to normobaric oxygen (NBO 101 kPa) StO(2) increased from 83% (82-85%, median and interquartile range) to 85% (84-87%) (P < 0.01), while when switching from air at pressure (59 kPa O(2)) to HBO (280 kPa), StO(2) increased from 85% (85-86%) to 88% (87-89%) (P < 0.001). There was no difference between baseline StO(2) while air breathing before NBO or after decompression. Values did not reach the maximal value of 100% at any point. The changes in hemoglobin oxygen saturation in tissue registered by the NIRS monitor when switching from air to oxygen followed inspired PO(2) under normobaric and hyperbaric conditions.
More Related Videos
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...