Related Experiment Video
Updated: Jun 15, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
New low-field extremity MRI, compacTscan: comparison with whole-body 1.5 T conventional MRI
Takeshi Suzuki1, Satoshi Ito, Shinya Handa
1Division of Clinical Immunology, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Abstract:
Low-field extremity magnetic resonance imaging (lfMRI) is currently commercially available and has been used clinically to evaluate rheumatoid arthritis (RA). However, one disadvantage of this new modality is that the field of view (FOV) is too small to assess hand and wrist joints simultaneously. Thus, we have developed a new lfMRI system, compacTscan, with a FOV that is large enough to simultaneously assess the entire wrist to proximal interphalangeal joint area. In this work, we examined its clinical value compared to conventional 1.5 tesla (T) MRI. The comparison involved evaluating three RA patients by both 0.3 T compacTscan and 1.5 T MRI on the same day. Bone erosion, bone edema, and synovitis were estimated by our new compact MRI scoring system (cMRIS) and the kappa coefficient was calculated on a joint-by-joint basis. We evaluated a total of 69 regions. Bone erosion was detected in 49 regions by compacTscan and in 48 regions by 1.5 T MRI, while the total erosion score was 77 for compacTscan and 76.5 for 1.5 T MRI. These findings point to excellent agreement between the two techniques (kappa = 0.833). Bone edema was detected in 14 regions by compacTscan and in 19 by 1.5 T MRI, and the total edema score was 36.25 by compacTscan and 47.5 by 1.5 T MRI. Pseudo-negative findings were noted in 5 regions. However, there was still good agreement between the techniques (kappa = 0.640). Total number of evaluated joints was 33. Synovitis was detected in 13 joints by compacTscan and 14 joints by 1.5 T MRI, while the total synovitis score was 30 by compacTscan and 32 by 1.5 T MRI. Thus, although 1 pseudo-positive and 2 pseudo-negative findings resulted from the joint evaluations, there was again excellent agreement between the techniques (kappa = 0.827). Overall, the data obtained by our compacTscan system showed high agreement with those obtained by conventional 1.5 T MRI with regard to diagnosis and the scoring of bone erosion, edema, and synovitis. We conclude that compacTscan is useful for diagnosis and estimation of disease activity in patients with RA.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI

