Related Experiment Video
Updated: Jun 15, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Preparation, characterisation and modification of carbon-based monolithic rods for chromatographic applications
Ali H Eltmimi1, Leon Barron, Aran Rafferty
1Irish Separation Science Cluster, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland.
Abstract:
A range of porous carbon-based monolithic (PCM) rods with flow-through pore sizes of 1, 2, 5 and 10 mum, were produced using a silica particle template method. The rods were characterised using SEM and energy-dispersive X-ray spectroscopy, BET surface area and porous structure analysis, dilatometry and thermal gravimetry. SEM evaluation of the carbon monolithic structures revealed an interconnected rigid bimodal porous structure and energy-dispersive X-ray spectroscopy analysis verified the quantitative removal of the embedded silica beads. The specific surface areas of the 1, 2, 5 and 10 mum rods were 178, 154, 84 and 125 m(2)/g after pyrolysis and silica removal, respectively. Shrinkage of the monolithic rods during pyrolysis is proportional to the particle size of the silica used and ranged from 9 to 12%. Mercury porosimetry showed a narrow distribution of pore sizes, with an average of approximately 700 nm for the 1 mum carbon monolith. The suitability of bare and surface oxidised PCM rods for the use as a stationary phase for reversed and normal phase LC was explored. The additional modification of PCM rods with gold micro-particles followed by 6-mercaptohexanoic acid was performed and ion-exchange properties were evaluated.
Related Concept Videos
Principles Of Column Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...